Difference between revisions of "GCode Header"
|  (→Sample Header) |  (→Sample Header) | ||
| Line 18: | Line 18: | ||
| This is what your header recipe will look like in Slic3r: | This is what your header recipe will look like in Slic3r: | ||
| − |   ;  | + |   ; '''REPORTING/ABORTING''' : | 
|   <span style="color: darkorange;">N14                ; set line numbers for error logging - Slic3r version |   <span style="color: darkorange;">N14                ; set line numbers for error logging - Slic3r version | ||
| Line 24: | Line 24: | ||
|   <span style="color: darkorange;">M627 X0 Y0 Z0 J-500 K5                 ; setup abort action</span> |   <span style="color: darkorange;">M627 X0 Y0 Z0 J-500 K5                 ; setup abort action</span> | ||
| − | + |   <span style="color: black;">;  | |
| − |   <span style="color: black;">M107               ; fans/UV           ; off | + |  M107               ; fans/UV           ; off | 
|   M106 C255          ; fans/UV           ; set to 0-255 range |   M106 C255          ; fans/UV           ; set to 0-255 range | ||
Revision as of 19:50, 20 April 2021
| Contents | 
At Hyrel, we believe that you must start with a good GCode header to get a good print. Below are explanations of our standard header files. These can be configured in Slic3r under Printer Settings > Custom G-code > Start G-code
Sample Header
- BLACK entries are for every machine
- GREEN entries are recommended, but must be manually entered
- RED entries are for the EHR only
- BLUE entries are for the 16A only
- PURPLE entries are explanations
- GOLD entries are optional, but recommended
This is what your header recipe will look like in Slic3r:
; REPORTING/ABORTING :
N14                ; set line numbers for error logging - Slic3r version
M772 S1            ; reset metrics and arm automatic reporting 
M627 X0 Y0 Z0 J-500 K5                 ; setup abort action
; 
M107               ; fans/UV           ; off
M106 C255          ; fans/UV           ; set to 0-255 range
G53                ; clear offsets
G21                ; units             : mm
G91                ; coordinatess      : relative
G0 Z10 	           ; drop bed 
G90                ; coordinates       : absolute
G28 X0 Y0          ; home, goto        : X and Y
M229 E1 D1         ; enable E-values (volumetric)
; TEMP CONTROL :
;M190 S[bed_temperature]          ; bed temp     : set and wait
;M109 T12 S[temperature]        ; head temp    : set and wait
T2                 ; use THIRD tool position from the left    