|   <span style="color: darkorange;">M627 X0 Y0 Z0 J-500 K5                 ; setup abort action</span> |   <span style="color: darkorange;">M627 X0 Y0 Z0 J-500 K5                 ; setup abort action</span> | ||
| − |   <span style="color: black;">;   | + |   <span style="color: black;">; '''RANGE SETUP''' | 
| + | |||
|   M107               ; fans/UV           ; off |   M107               ; fans/UV           ; off | ||
|   M106 C255          ; fans/UV           ; set to 0-255 range |   M106 C255          ; fans/UV           ; set to 0-255 range | ||
| + |  <span style="color: black;">; '''OFFSETS and POSITIONING''' | ||
| + | |||
|   G53                ; clear offsets |   G53                ; clear offsets | ||
|   G21                ; units             : mm |   G21                ; units             : mm | ||
| Line 33: | Line 36: | ||
|   G0 Z10 	           ; drop bed   |   G0 Z10 	           ; drop bed   | ||
|   G90                ; coordinates       : absolute |   G90                ; coordinates       : absolute | ||
| − | |||
|   G28 X0 Y0          ; home, goto        : X and Y |   G28 X0 Y0          ; home, goto        : X and Y | ||
| + |  <span style="color: darkorange;">M229 E1 D1         ; enable E-values (volumetric) | ||
| − | + |   <span style="color: black;">; '''HEAD DESIGNATION''' : | |
| − | + | ||
| − |   ;  | + |   T2                 ; use THIRD tool position from the left  | 
| − | + |   <span style="color: black;">; '''TEMPERATURE CONTROL''' : | |
| − | |||
| − | + |   M190 S[bed_temperature]          ; bed temp     : set and wait | |
| + |  M109 T12 S[temperature]        ; head temp    : set and wait    | ||
Revision as of 19:52, 20 April 2021
| Contents | 
At Hyrel, we believe that you must start with a good GCode header to get a good print. Below are explanations of our standard header files. These can be configured in Slic3r under Printer Settings > Custom G-code > Start G-code
Sample Header
- BLACK entries are for every machine
- GREEN entries are recommended, but must be manually entered
- RED entries are for the EHR only
- BLUE entries are for the 16A only
- PURPLE entries are explanations
- GOLD entries are optional, but recommended
This is what your header recipe will look like in Slic3r:
; REPORTING/ABORTING :
N14                ; set line numbers for error logging - Slic3r version
M772 S1            ; reset metrics and arm automatic reporting 
M627 X0 Y0 Z0 J-500 K5                 ; setup abort action
; RANGE SETUP
M107               ; fans/UV           ; off
M106 C255          ; fans/UV           ; set to 0-255 range
; OFFSETS and POSITIONING
G53                ; clear offsets
G21                ; units             : mm
G91                ; coordinatess      : relative
G0 Z10 	           ; drop bed 
G90                ; coordinates       : absolute
G28 X0 Y0          ; home, goto        : X and Y
M229 E1 D1         ; enable E-values (volumetric)
; HEAD DESIGNATION :
T2                 ; use THIRD tool position from the left 
; TEMPERATURE CONTROL :
M190 S[bed_temperature]          ; bed temp     : set and wait
M109 T12 S[temperature]        ; head temp    : set and wait   